2014. december 16., kedd 08:30 |
Korean scientists publish the latest results on colorectal cancer screening using the M2-PK test in the renowned journal Gut and Liver' |
|
Seoul, 16 December, 2014 (APA/OTS) - Scientists from the College
of Medicine at the Catholic University of Korea have published
newest data on the M2-PK test from a multi-center study of
colorectal cancer screening in the journal Gut and Liver'. The
results from cancer expert Professor Yong Kim and his colleagues
confirm the exceptionally high capability of the M2-PK test,
particularly in comparison to the immunological fecal occult blood
test (iFOBT), to detect adenomas and colorectal cancer. |
In their study Professor Kim and colleagues investigated the
enzymatic biomarker M2-PK with volunteers in patient groups with 139
cases of colorectal cancer and 124 with adenoma, along with a
population-based control group of 60 people, making a total of 323
subjects. The sensitivity of the M2-PK test was 92.8% for colorectal
cancer and 69.4% for adenomas. In addition, they also compared the
results of the M2-PK test with those of an immunological fecal
occult blood test (iFOBT). This was clearly inferior to the M2-PK
test. The iFOBT detected only 47.5% of the colon cancers and just
12.1% of the adenomas. Consequently, the M2-PK test detected twice
as many colorectal cancer cases and nearly six times the number of
adenomas than the immunological fecal occult blood test (iFOBT).
These scientific results from the University of Korea categorically
confirm the capability of the fecal M2-PK test for screening and
early detection of colorectal cancer.
The fecal M2-PK test is available as a qualitative rapid test under
the name ScheBo® M2-PK QuickTM and as a fully quantitative ELISA
stool test.
Picture is available via epa european pressphoto agency (
http://www.epa.eu/ ) and can be downloaded free of charge at:
http://www.presseportal.de/pm/28702/schebo-biotech-ag?keygroup=bild
Source: Kim YC, et al., Gut and Liver, online December 5th, 2014;
http://dx.doi.org/10.5009/gnl13457 , www.gutnliver.org/ .
Contact: ScheBo (R) oBiotech AG / Tel: +49-(0)641-4996-0 / Fax:
+49-(0)641-4996-78 www.schebo.com
-------------------------------------------------------------------
Az OTS internetes oldalán található hírek, közlemények, fotók
a forrásmegjelöléssel (OTS) szabadon és korlátozás nélkül
felhasználhatók. Továbbközlés esetén a közzétevő köteles az átvett
anyagot tartalmának torzítása nélkül, félreérthetőséget,
rosszindulatú következtetéseket kizáró, az eredeti
szövegkörnyezetnek megfelelő módon feldolgozni és megjelentetni.
Az OTS hírek nem képezik az MTI hírkiadás részét, az MTI által
szó szerint továbbított tartalomért minden esetben a beadó a felelős. © Copyright MTI nonprofit Zrt.
Az OTS szolgáltatással kapcsolatban további információt a
(06-1) 441-9050 telefonszámon vagy a ots@mti.hu elektronikus
levelező címen kaphat.
|
|
|
|
|
|
|
Forrás: OTS Üzleti Sajtószolgálat
MTI © Minden jog fenntartva.
|